Long-term obturation quality using noninstrumentation technology

Citation
A. Lussi et al., Long-term obturation quality using noninstrumentation technology, J ENDODONT, 26(9), 2000, pp. 491-493
Citations number
18
Categorie Soggetti
Dentistry/Oral Surgery & Medicine
Journal title
JOURNAL OF ENDODONTICS
ISSN journal
00992399 → ACNP
Volume
26
Issue
9
Year of publication
2000
Pages
491 - 493
Database
ISI
SICI code
0099-2399(200009)26:9<491:LOQUNT>2.0.ZU;2-R
Abstract
The aim of the study was to evaluate and compare the sealing quality of han d- or vacuum-obturated root canals after hand instrumentation or noninstrum entation cleansing. A total of 60 single-rooted teeth were divided into six comparable groups. The root canals of three groups were instrumented with the balanced-force technique and obturated with gutta-percha condensation. The remaining teeth were cleansed and filled using noninstrumentation techn ology and the same sealers as with hand instrumentation (AH Plus, Apexit, P ulp canal sealer EWT). After aging the quality of coronal seal was assessed with a dye penetration method after perfusion with the dye under vacuum. T he results of this study indicated superior sealing of the machine-filled r oots (noninstrumentation technology), compared with laterally condensed con ventionally filled root canals.