Magnetic and thermal performance of a synchronous motor under loss minimization control

Citation
C. Mademlis et al., Magnetic and thermal performance of a synchronous motor under loss minimization control, IEEE EN CON, 15(2), 2000, pp. 135-142
Citations number
17
Categorie Soggetti
Environmental Engineering & Energy
Journal title
IEEE TRANSACTIONS ON ENERGY CONVERSION
ISSN journal
08858969 → ACNP
Volume
15
Issue
2
Year of publication
2000
Pages
135 - 142
Database
ISI
SICI code
0885-8969(200006)15:2<135:MATPOA>2.0.ZU;2-#
Abstract
The steady state magnetic and thermal performance of a wound-field cylindri cal rotor synchronous motor under loss minimization control is investigated , The calculated magnetic field waveforms are presented and it is shown tha t loss minimization control decreases the magnetic saturation. It is also p roved that although the optimal stator current is increased, the temperatur e is decreased in all parts of the motor. Theoretical and experimental resu lts are presented to verify the operational improvements.