Non-contacting residual stress decay detecting using alternating current stress measurement

Citation
K. Chen et al., Non-contacting residual stress decay detecting using alternating current stress measurement, J STRAIN A, 35(4), 2000, pp. 227-233
Citations number
9
Categorie Soggetti
Mechanical Engineering
Journal title
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN
ISSN journal
03093247 → ACNP
Volume
35
Issue
4
Year of publication
2000
Pages
227 - 233
Database
ISI
SICI code
0309-3247(200007)35:4<227:NRSDDU>2.0.ZU;2-2
Abstract
Recent work conducted at the Non-Destructive Evaluation Centre of Universit y College London on the residual stress decay detection using the new alter nating current stress measurement (ACSM) technology is presented. Flat bar mild steel specimens were used in the experimental study. An equal biaxial compressive residual stress field was introduced into the specimen surfaces by shot peening. The specimens were then subjected to a constant-amplitude cyclic load on a fatigue-testing machine. Under this loading situation, ho le-drilling tests indicated that only the residual stress component in the cyclic loading direction had significantly relaxed. Test results showed tha t this relaxation could be detected by using the existing ACSM system. Furt her theoretical and experimental efforts are needed to make this technology available for a wide range of practical applications.