Finite element analyses (FEAs) have been widely used to preventively predic
t the reliability issues of flip-chip (FC) packages. The validity of the si
mulation results strongly depends on the inputs of the involved material pr
operties, For FC packages Young's modulus-temperature relationship is a cri
tical material property in predicting of the package reliability during -55
degrees C to 125 degrees C thermal cycling, Traditional tensile tests can
obtain the modulus at-selected temperatures, but it is tedious, expensive,
and unable to accurately predict the Young's modulus-temperature relationsh
ip within a wide temperature range. Thus, this paper is targeted,to provide
a simple but relatively accurate methodology to obtain the Young's modulus
-temperature relationship. In this paper, three commercial silica filled un
derfill materials were studied, A simple specimen (based on ASTM D638M) pre
paration method was established using a Teflon mold. A dynamic-mechanical a
nalyzer (DMA) was used to obtain the stress-strain relationship under contr
olled force mode, storage and loss modulus under multi-frequency mode, and
stress relaxation under stress relaxation mode, A simple viscoelastic model
was used and an empirical methodology for obtaining Young's modulus-temper
ature relationship was established.