Remodeling of JT-60 discharge control system

Citation
I. Yonekawa et al., Remodeling of JT-60 discharge control system, FUSION ENG, 48(1-2), 2000, pp. 17-23
Citations number
3
Categorie Soggetti
Nuclear Emgineering
Journal title
FUSION ENGINEERING AND DESIGN
ISSN journal
09203796 → ACNP
Volume
48
Issue
1-2
Year of publication
2000
Pages
17 - 23
Database
ISI
SICI code
0920-3796(200008)48:1-2<17:ROJDCS>2.0.ZU;2-H
Abstract
Remodeling of the JT-60 discharge control system (DCS) is initiated to mini mize the cost and time for hardware maintenance and software development. T hree principles have been adopted for remodeling. (1) The functions of the DCS must remain intact. (2) The shutdown period must be minimized to maximi ze JT-60 experiment time. To realize the new DCS, (3) a combination of the host workstation (WS) and target Versa Module Europe (VME)-bus system with real time OS was chosen as the fundamental structure. The prototype DCS was designed and tested to evaluate the performance of the converted discharge sequential control software modules and the message communication program. The new configuration of the DCS and procedure of smooth remodeling withou t shutdown is described in detail. (C) 2000 Elsevier Science S.A. All right s reserved.