Silicon-CsI detector array for heavy-ion reactions

Citation
E. Noreck et al., Silicon-CsI detector array for heavy-ion reactions, NUCL INST A, 452(1-2), 2000, pp. 239-244
Citations number
7
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
452
Issue
1-2
Year of publication
2000
Pages
239 - 244
Database
ISI
SICI code
0168-9002(20000921)452:1-2<239:SDAFHR>2.0.ZU;2-1
Abstract
An array of 60 silicon-CsI(T1) detector telescopes has been developed along with associated electronics, The close packing of the telescopes required novel designs for the photodiodes and the silicon Delta E detectors. Newly developed electronics include preamplifers, shaping amplifiers, test pulse circuitry, and a module to monitor leakage currents in the silicon diodes. The array covers angles from 5 degrees to 18 degrees in the 4 pi Array at t he National Superconducting Cyclotron Laboratory at Michigan State Universi ty. It measures protons to 150 MeV and has isotopic resolution for intermed iate mass nuclei. (C) 2000 Published by Elsevier Science B.V. All rights re served.