To expedite the fabrication of reinforcement cages of columns, a new config
uration of transverse reinforcement with alternate ties for columns is prop
osed. To evaluate the effect of such a configuration on the seismic perform
ance of the column, nine reinforced concrete columns with a cross section o
f 400 X 400 mm were tested. Except for the transverse reinforcement, all co
lumns were designed according to the seismic provisions of the American Con
crete Institute. The tie configuration and axial load were the two main par
ameters investigated in the experimental program. It was found from the tes
t results that the proposed configuration of transverse reinforcement provi
des comparable or improved seismic performance in terms of member ductility
and energy dissipation capacity to those usually used in design, and the r
equirement for compression lap splice in the ties is also adequate when the
proposed alternate configuration of transverse reinforcement is used.