We report a series of 38 patients with intra-uterine devices with lost stri
ngs where hysteroscopic aid was required after routine retrieval procedures
failed. Thirty-five intra-uterine devices could be removed easily with hys
teroscope. In one patient a fragmented Lippes Loop was removed piecemeal hy
steroscopically Laparotomy was required in only one patient, for an extra-u
terine Copper T Hysteroscopy is thus a simple, safe and effective method fo
r removing misplaced intra-uterine devices.