A new and quick spectrophotometric method was developed to assess deep-fryi
ng oil quality. The scanned spectrophotometric curves of the frying oil sam
ples from 350 and 650 nm wavelength changed systematically with the duratio
n of deep frying. The absorbances of the frying oil samples, especially tho
se measured at 490 nm, increased significantly during frying and were signi
ficantly correlated to frying time (I greater than or equal to 0.95, P < 0.
001). There was a strong correlation between the absorbances of a set of oi
l samples taken from 0 to 80 h of deep frying and total polar compound cont
ents in the same set of oil samples analyzed using the American Oil Chemist
s' Society official method (r = 0.924, P < 0.001). The equation for convers
ion of the absorbances to total polar compound contents is y = -2.7865x(2)
+ 23.782x + 1.0309. The absorbances of 10 different types of frying oils wi
th samples taken from 0 to 80 h of deep frying in duplicate were also stron
gly correlated to total polar compounds in the same oil samples (r = 0.953,
P < 0.001, n = 220). The results show that this method is fast, simple, co
nvenient, and reliable.