On the basis that a gas/liquid two-phase flow was considered as a stro
ngly inhomogeneous medium due to the high contrast in acoustic impedan
ce distribution, the authors analysed the inherent dependency of the i
ncomplete tomographic projections on the distribution of bubbles in li
quid when using transmission-mode (TM) ultrasound computerized tomogra
phy (UCT). A mathematical model describing the acoustic characteristic
s of this flow was established. A transmission-mode ultrasonic system
for tomographic imaging of gas/liquid flow was designed based upon a f
ast binary back-projection image reconstruction algorithm. Emphasis wa
s made on the evaluation of its performance and its application to flo
w regime identification. Several flow pattern models were made and the
corresponding monitoring results were given. Finally, limitations and
possible future implementations of the system are discussed. (C) 1997
Elsevier Science Ltd. All rights reserved.