ELECTRICAL TESTING OF LARGE-SCALE IR-AND-D DUMMY COIL FOR TPX MAGNET INSULATION DESIGN VERIFICATION

Citation
Jf. Roach et al., ELECTRICAL TESTING OF LARGE-SCALE IR-AND-D DUMMY COIL FOR TPX MAGNET INSULATION DESIGN VERIFICATION, IEEE transactions on applied superconductivity, 7(2), 1997, pp. 473-476
Citations number
2
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
10518223
Volume
7
Issue
2
Year of publication
1997
Part
1
Pages
473 - 476
Database
ISI
SICI code
1051-8223(1997)7:2<473:ETOLID>2.0.ZU;2-S
Abstract
Electrical test results are reported characterizing the dielectric pro perties, insulation capability, and equivalent circuit parameters of a 1.8 m OD, 24 turn IR&D dummy coil built by the Westinghouse TPX Team to address magnet coil manufacturing issues and to verify electrical i nsulation design for TPX PF and TF magnet coils. Induced voltage tests at 77 K were performed at the National High Magnetic Field Laboratory (NHMFL) to 200 V per turn without dielectric failure. High voltage te sting was performed at Everson Electric under room temperature factory conditions. The coil turn insulation was surge tested to 21 kV withou t failure. The coil groundwall insulation was hipot tested up to 58 kV with 48 kV minimum withstand to the imbedded groundplane screen elect rode, The coil was sectioned and examined for insulation impregnation quality and manufacturing tolerances.