MAGNETIC MEASUREMENTS OF LARGE-APERTURE SUPERCONDUCTING QUADRUPOLE MAGNETS FOR TJNAFS HIGH MOMENTUM SPECTROMETER

Citation
Sr. Lassiter et al., MAGNETIC MEASUREMENTS OF LARGE-APERTURE SUPERCONDUCTING QUADRUPOLE MAGNETS FOR TJNAFS HIGH MOMENTUM SPECTROMETER, IEEE transactions on applied superconductivity, 7(2), 1997, pp. 614-617
Citations number
4
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
10518223
Volume
7
Issue
2
Year of publication
1997
Part
1
Pages
614 - 617
Database
ISI
SICI code
1051-8223(1997)7:2<614:MMOLSQ>2.0.ZU;2-7
Abstract
The results of the field mapping measurements of Thomas Jefferson Nati onal Accelerator Facility's three large aperture, cold iron, laminated yoke superconducting quadrupole magnets for the High Momentum Spectro meter will be presented. These magnets were mapped using a rotating co il assembly housed within a G-10 drum. A description of the apparatus and technique used to map the magnets over an excitation range of 0 to 2 tesla will be described. This method of mapping provides for an alm ost real time measurement of field strength, effective field length, f ield gradient, transfer function and the determination of symmetry pla nes. The hysteresis loop and affects of eddy currents will be shown. A comparison of the measured field values with calculated values will a lso be given.