D. Canac-arteaga et al., Analytical artifacts caused by the presence of water vapor in the headspace of food products, ANALUSIS, 28(6), 2000, pp. 550-556
Artifacts due to water that appear during analysis by purge-and-trap/GC/MS
of naturally moist products were reproduced by increasing the relative humi
dity of the headspace of measuring cell containing dry and low-moisture pro
ducts (dehydrated beef stock and powdered Parmesan cheese) by means of a pi
ece of moistened glass wool. The changes observed in the chromatographic pr
ofiles of the dry products after humidifying the headspace are explained by
interactions between volatile compounds, water and the adsorption trap dur
ing the purge-and-trap step.