Neutron irradiation studies with detector grade CVD diamond

Citation
A. Oh et al., Neutron irradiation studies with detector grade CVD diamond, DIAM RELAT, 9(11), 2000, pp. 1897-1903
Citations number
14
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Material Science & Engineering
Journal title
DIAMOND AND RELATED MATERIALS
ISSN journal
09259635 → ACNP
Volume
9
Issue
11
Year of publication
2000
Pages
1897 - 1903
Database
ISI
SICI code
0925-9635(200011)9:11<1897:NISWDG>2.0.ZU;2-3
Abstract
Detector grade CVD diamond samples have been irradiated with neutrons from a spallation source with an average energy of 5 MeV up to fluences of 6.5 x 10(15) n cm(-2). After each irradiation stage the samples were characteris ed in terms of their charge collection efficiency, priming ratio and primin g dose. It was found that the charge collection efficiency degrades with in creasing neutron fluence for all investigated samples. The sensitivity to n eutron radiation is found to be strongly sample-dependent. The experimental data can be well described by a simple damage model. (C) 2000 Elsevier Sci ence B.V. All rights reserved.