If. Mao et al., Sampling efficiency of a modified closed-face cassette sampler for airborne toluene diisocyanate determination, INT A OCCUP, 73(8), 2000, pp. 570-574
Citations number
29
Categorie Soggetti
Envirnomentale Medicine & Public Health","Pharmacology & Toxicology
Journal title
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH
Objectives: A modified closed-face cassette was developed for sampling and
derivatizing airborne toluene diisocyanate (TDI). Methods: The cassette was
assembled as a regular two-piece cassette sampler except that the whole in
ner surface of the sampler was loaded with coated filters to ensure that al
l of the aspirated TDI react with 1-(2-pyridyl) piperazine (1-2pp). Results
: A test atmosphere study showed that the sampling efficiencies were 89.4%
and 94.3% for 2,4-TDI and 2.6-TDI. One-third of the 2,4-TDI and 2,6-TDI mas
s was constantly collected on the top and middle-rim filters. A polyurethan
e (PU)-manufacturing plant study revealed an average of 35% and 33% of both
isomer masses collected on the top and middle-rim filters. The 2,4-TDI col
lection of the closed-face cassette sampling was 21% higher than that of op
en-face sampling. Furthermore, consistent isomeric compositions of airborne
2,4-/2,6-TDI obtained from both types of samplers validated the use of the
modified cassette sampler. Conclusions: The closed-face cassette sampler i
s capable of a higher collection of airborne TDI and the technique involved
is as simple and feasible as that of the open-face sampler.