THE DEVELOPMENT OF A HIGH-T-C MAGNETOCARDIOGRAPHY SYSTEM FOR UNSHIELDED ENVIRONMENT

Citation
B. David et al., THE DEVELOPMENT OF A HIGH-T-C MAGNETOCARDIOGRAPHY SYSTEM FOR UNSHIELDED ENVIRONMENT, IEEE transactions on applied superconductivity, 7(2), 1997, pp. 3267-3270
Citations number
14
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
10518223
Volume
7
Issue
2
Year of publication
1997
Part
3
Pages
3267 - 3270
Database
ISI
SICI code
1051-8223(1997)7:2<3267:TDOAHM>2.0.ZU;2-O
Abstract
A modular, 9-channel high-T-c SQUID system for magnetocardiography (MC G) was developed and tested in unshielded environment. Galvanically-co upled magnetometers made from Y-Ba-Cu-O films, with intrinsic white no ise levels as low as 70 fT/root Hz, are used as SQUID sensors. In unsh ielded environment, a noise level of about 1 pT/root Hz for each chann el was achieved using an active noise compensation system. A new digit al planar gradiometer is proposed. First magnetocardiograms recorded i n unshielded environment are presented.