Transcatheter atrial septal defect occlusion in piglets by balloon detachable devices

Citation
Eb. Sideris et al., Transcatheter atrial septal defect occlusion in piglets by balloon detachable devices, CATHET C IN, 51(4), 2000, pp. 529-534
Citations number
19
Categorie Soggetti
Cardiovascular & Respiratory Systems
Journal title
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
ISSN journal
15221946 → ACNP
Volume
51
Issue
4
Year of publication
2000
Pages
529 - 534
Database
ISI
SICI code
1522-1946(200012)51:4<529:TASDOI>2.0.ZU;2-H
Abstract
Detachable balloon devices were applied in the occlusion of experimental AS Ds in 20 piglets, The detachable balloons were made from Latex; the occlude r balloon was placed on the left atrial side and required a floppy disk and counter-occluder(s) support from the right atrial side (17 experiments), o r a second detachable balloon from the right side (3 experiments). Full occ lusion was noticed in all cases. There was one device embolization in the d escending aorta (device with a regular floppy disk and no counter-occluder) . The device was covered by tissue in 3 to 4 weeks with the balloon flat on the septum in approximately 2 months; it required minimal rim and no wires in the left atrium, The double balloon model was wireless, The balloon det achable device was found effective and safe in the occlusion of experimenta l ASDs in piglets. Cathet Cardiovasc. Intervent 51:529-534, 2000. (C) 2000 Wiley-Liss, Inc.