Voltammetric and chronopotentiometric measurements with nucleic acid-modified mercury film on a glassy carbon electrode

Citation
T. Kubicarova et al., Voltammetric and chronopotentiometric measurements with nucleic acid-modified mercury film on a glassy carbon electrode, ELECTROANAL, 12(17), 2000, pp. 1390-1396
Citations number
38
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ELECTROANALYSIS
ISSN journal
10400397 → ACNP
Volume
12
Issue
17
Year of publication
2000
Pages
1390 - 1396
Database
ISI
SICI code
1040-0397(200011)12:17<1390:VACMWN>2.0.ZU;2-B
Abstract
Mercury film plated on a glassy carbon electrode was used for the analysis of nucleic acids. Using voltammetry in cyclic, square-wave and alternating current modes and constant current chronopotentiometry redox as well as ten sammetric signals of DNA, RNA and synthetic polynucleotides were obtained. Behavior of nucleic acids at the mercury film electrode (MFE) was compared with that observed previously at HMDE. Nucleic acid-modified MFE appeared s uitable for various applications.