B. Vermeulen et Jp. Remon, Validation of a high-performance liquid chromatographic method for the determination of ibuprofen enantiomers in plasma of broiler chickens, J CHROMAT B, 749(2), 2000, pp. 243-251
To characterise the pharmacokinetic properties of each enantiomer of ibupro
fen in broiler chickens, a stereospecific HPLC method based on a alpha (1)-
acid glycoprotein bonded chiral stationary phase has been validated. S-(+)-
naproxen was used as internal standard. Enantiomers of ibuprofen and S-(+)-
naproxen were baseline separated using a mobile phase consisting of 0.1 M p
hosphate buffer pH=7 and 0.4% 2-propanol. The method is precise, specific,
accurate and reproducible. Recoveries were higher than 80% and the limits o
f quantification for R-(-)- and S-(+)-ibuprofen were 1.16 and 1.37 mug ml(-
1), respectively. The method seemed suitable fur the pharmacokinetic studie
s of ibuprofen in chickens. (C) 2000 Elsevier Science B.V. All rights reser
ved.