Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence

Citation
Jt. Winterer et al., Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence, J COMPUT AS, 24(6), 2000, pp. 903-908
Citations number
21
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Journal title
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY
ISSN journal
03638715 → ACNP
Volume
24
Issue
6
Year of publication
2000
Pages
903 - 908
Database
ISI
SICI code
0363-8715(200011/12)24:6<903:OOCMAO>2.0.ZU;2-V
Abstract
Our objective was to optimize bolus administration and sequence setting in gadolinium-enhanced magnetic resonance (MR) angiography of the hands. Ellip tically reordered three-dimensional (3D) spoiled gradient-echo sequence wit h non-slab-selective radio frequency excitation was optimized according to the measurements of arterial and venous time-signal curves in 21 patients. Great variations in bolus arrival time and arterio-venous transit time coul d be observed. In most patients high-quality arterial depiction could be ob tained with minor venous contamination. Contrast-to-noise, spatial resoluti on, and selective arterial filling is still a challenge for 3D MR angiograp hy of the hand but can be optimized using Gadolinium-BOPTA and a dedicated pulse sequence setting with exact bolus timing.