One of two alloy 904L (UNS N08904) wiped film evaporators, operating in ser
ies on tall oil, failed after tl year. The form of failure was deep circumf
erential grooving of the shell and wipers. Mechanical wear and corrosion we
re evaluated as causes. Outside engineers were consulted and, after investi
gation, concluded that it was a corrosion failure, They recommended upgradi
ng materials to an austenitic stainless steel (SS) containing 6% molybdenum
. The plant owners believed wear to be the cause, however, and the replacem
ent was made mainly from type 317L SS (S31703).