Determination of the optimal dose of polyelectrolyte sludge conditioner considering particle sedimentation effects

Citation
Cc. Wu et al., Determination of the optimal dose of polyelectrolyte sludge conditioner considering particle sedimentation effects, ADV ENV RES, 4(3), 2000, pp. 245-249
Citations number
9
Categorie Soggetti
Environmental Engineering & Energy
Journal title
ADVANCES IN ENVIRONMENTAL RESEARCH
ISSN journal
10930191 → ACNP
Volume
4
Issue
3
Year of publication
2000
Pages
245 - 249
Database
ISI
SICI code
1093-0191(200008)4:3<245:DOTODO>2.0.ZU;2-4
Abstract
The specific resistance to filtration (SRF) of sludge was determined using both a leaf filter and a Buncher funnel. The filterability of a kaolin susp ension and an alum sludge were characterized using SRF data and capillary s uction time (CST) measurements. Filter orientation during the leaf filter t est and stirring during the Buncher funnel test affected the SRF values, an d the optimal dosage of polyelectrolyte conditioner (defined as the dosage that yields the minimum resistance to filtration) varied depending on the t ype of test used. Therefore, the optimal dose of polyelectrolyte was an ope rationally defined value that depended on the geometry of the filter chambe r and fluid/particle interactions, such as sedimentation. (C) 2000 Elsevier Science Ltd. All rights reserved.