The single-phase PWM current-fed inverter has some feasible advantages for
utility-interactive systems. In particular, it is more suitable for the non
-isolated type of utility-interactive system topology that is widely used f
or residential photovoltaic power generation systems in Japan. But, this so
rt of inverter has a significant disadvantage. The output current of the in
verter includes large harmonic components when its smoothing reactor is not
large enough to eliminate its current ripple component. This paper present
s a new control strategy to reduce sufficiently the harmonic component of t
he single-phase current-fed PWM inverter, even when the ripple current in t
he smoothing reactor is large. The principle of the proposed control strate
gy for this inverter system is described and its simulation results are eva
luated.