The influence of a ground shield on the heat flux to a substrate in a paral
lel-plate plasma system was investigated experimentally using an original t
emperature measurement technique. The evaluation of the temperature rise cu
rve shows that the heat flux from the plasma towards the substrate increase
s from 8% of the rf power to 26% by surrounding the powered electrode with
the ground shield. The flux density on the powered electrode is 350 W m(-2)
at an rf power of 50 W and pressure of 50 mTorr, and the value increases t
o 1150 W m(-2) by shielding. However, the total power into the electrode is
23-26% of the rf power in both cases, after accounting for the larger plas
ma facing surface area of the unshielded system. By shielding, a self-bias
voltage decreases from 80% of the applied rf voltage to 73% due to a contra
cted spatial distribution of the electron density between the electrodes by
shielding. The ion Bur is smaller than the heat flux obtained from the sub
strate temperature rise and it increases by shielding.