TONNERRE: an array for delayed-neutron decay spectroscopy

Citation
A. Buta et al., TONNERRE: an array for delayed-neutron decay spectroscopy, NUCL INST A, 455(2), 2000, pp. 412-423
Citations number
30
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
455
Issue
2
Year of publication
2000
Pages
412 - 423
Database
ISI
SICI code
0168-9002(200012)455:2<412:TAAFDD>2.0.ZU;2-Z
Abstract
The design and construction of an array for delayed-neutron decay spectrosc opy is presented. The array is composed of 32 plastic scintillator (BC400) modules each of which provide for time-of-flight (energy) and position meas urements. The intrinsic detection efficiency is 30% at E-n = 2 MeV and the resolution deltaE(n)/E-n similar to 10% (FWHM). The array can cover a total solid angle of up to 50% of 4 pi. Details of studies performed to optimize the performances of the individual modules are reported, as well as source testing and in-beam commissioning. (C) 2000 Elsevier Science B.V. All righ ts reserved.