AC loss measurement of Bi-2223 conductors

Citation
Mh. Jang et al., AC loss measurement of Bi-2223 conductors, PHYSICA C, 341, 2000, pp. 2575-2576
Citations number
4
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
PHYSICA C
ISSN journal
09214534 → ACNP
Volume
341
Year of publication
2000
Part
4
Pages
2575 - 2576
Database
ISI
SICI code
0921-4534(200011)341:<2575:ALMOBC>2.0.ZU;2-Y
Abstract
In this paper, AC losses of Bi-2223 tapes with different matrix of supercon ducting core were measured and analyzed. The two samples produced by a powd er-in-tube method are multi-filamentary tape with Ag and Ag-Au matrix The m easurement was carried out under the environment of constant transport curr ent and applied time-varying magnetic held. From experiment, losses for fie lds applied parallel to the c-axis of the textured Bi-2223 grains are large r by over an order of magnitude than those applied perpendicular. And it is confirmed that conductor losses with Ag matrix are larger than those with Ag-Au matrix.