P. Boisrenoult et al., Biomechanical comparison of screw versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau, REV CHIR OR, 86(7), 2000, pp. 707-711
Citations number
14
Categorie Soggetti
Ortopedics, Rehabilitation & Sport Medicine
Journal title
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR
Purpose of the study
We compared in vitro the efficacy of screw-plate fixation versus double scr
ew fixation on a model of type 2 Schatzker fracture of the lateral tibial p
lateau.
Materials and methods
Ten screw-plate fixations using a lateral prebent plate and 10 double-screw
fixations (6.5 mm screws) were made on 10 pairs of non-embalmed cadaver kn
ees after simulation of type 2 Schatzker fractures. The strength of each fi
xation was tested with a compression device. Criteria indicating failure we
re displacements greater than 2 mm of one or more fracture lines. The force
applied at rupture and the stiffness of each type of fixation were compare
d. Wilcoxon's test was used for statistical analysis.
Results
Force at rupture and stiffness of the fixation were similar for the two typ
es of fixation. There was no statistical difference (p > 0.05) between the
screw-plate and the double-screw fixations.
Discussion
Our findings on a model of type 2 Schatzker fractures are in agreement with
previous data obtained by other authors working on models of type 1 Schats
ker fractures. The biomechanical stability of the double-screw fixation is
as good as that obtained with screw-plate fixation for the treatment of fra
ctures of the lateral tibial plateau.