The curvilinear variable axis lens concept for the PREVAIL proof-of-concept
(POC) system, and its practical implementation have been described in a pr
evious publication [H. C. Pfeiffer et al., J. Vac. Sci. Technol. B 6, 2844
(1999)]. The objective of this article is to show experimental results rega
rding the dynamic compensation of the deflection-dependent focus and astigm
atism aberration control in the projected subfield. The POC system contains
a plurality of dynamic correction elements in the imaging section between
reticle and wafer. Using a pair of properly positioned stigmators, we have
demonstrated nearly independent control of feature astigmatism (image quali
ty) and subfield distortion (shape astigmatism). In this article, we will d
escribe a technique that was used to control the subfield distortion. In ad
dition, using three dynamic focus coils, and an inverted sensitivity matrix
approach, we have also demonstrated independent control of the subfield ma
gnification, rotation, and axial focus. (C) 2000 American Vacuum Society. [
S0734-211X(00)05806-6].