PREVAIL: Dynamic correction of aberrations

Citation
Ms. Gordon et al., PREVAIL: Dynamic correction of aberrations, J VAC SCI B, 18(6), 2000, pp. 3079-3083
Citations number
8
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Material Science & Engineering
Journal title
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B
ISSN journal
10711023 → ACNP
Volume
18
Issue
6
Year of publication
2000
Pages
3079 - 3083
Database
ISI
SICI code
1071-1023(200011/12)18:6<3079:PDCOA>2.0.ZU;2-2
Abstract
The curvilinear variable axis lens concept for the PREVAIL proof-of-concept (POC) system, and its practical implementation have been described in a pr evious publication [H. C. Pfeiffer et al., J. Vac. Sci. Technol. B 6, 2844 (1999)]. The objective of this article is to show experimental results rega rding the dynamic compensation of the deflection-dependent focus and astigm atism aberration control in the projected subfield. The POC system contains a plurality of dynamic correction elements in the imaging section between reticle and wafer. Using a pair of properly positioned stigmators, we have demonstrated nearly independent control of feature astigmatism (image quali ty) and subfield distortion (shape astigmatism). In this article, we will d escribe a technique that was used to control the subfield distortion. In ad dition, using three dynamic focus coils, and an inverted sensitivity matrix approach, we have also demonstrated independent control of the subfield ma gnification, rotation, and axial focus. (C) 2000 American Vacuum Society. [ S0734-211X(00)05806-6].