Amperometric sensor based on NASICON and NO oxidation catalysts for detection of total NOx in atmospheric environment

Citation
M. Ono et al., Amperometric sensor based on NASICON and NO oxidation catalysts for detection of total NOx in atmospheric environment, SOL ST ION, 136, 2000, pp. 583-588
Citations number
26
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
SOLID STATE IONICS
ISSN journal
01672738 → ACNP
Volume
136
Year of publication
2000
Pages
583 - 588
Database
ISI
SICI code
0167-2738(200011)136:<583:ASBONA>2.0.ZU;2-7
Abstract
A NASICON based amperometric sensor was designed for the detection of total NO chi (NO + NO2) in air. To make the device sensitive to both NO2 and NO, the sensing electrode (Au) was covered with NO oxidation catalysts. With t he sensing electrode potential fixed at - 150 mV vs, reference electrode (A u), the device attached with double catalyst layers of WO, and Pt(0.5 wt%)- loaded SiO2 produced current response proportional to the concentration of NO2 or NO up to 1 ppm at 150 degreesC. In addition, the proportionality con stants (sensitivity) were almost the same to NO and NO2. The current respon ses were barely affected by the coexistence of CO2 or H2O. (C) 2000 Elsevie r Science B.V. All rights reserved.