Development of fast response calorimeter for neutral beam shine-through measurement on CHS

Citation
M. Osakabe et al., Development of fast response calorimeter for neutral beam shine-through measurement on CHS, REV SCI INS, 72(1), 2001, pp. 586-589
Citations number
8
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN journal
00346748 → ACNP
Volume
72
Issue
1
Year of publication
2001
Part
2
Pages
586 - 589
Database
ISI
SICI code
0034-6748(200101)72:1<586:DOFRCF>2.0.ZU;2-X
Abstract
A fast response calorimeter has been developed for the neutral-beam (NB) sh ine-through measurement. This calorimeter has the following advantages. (1) Temporal variation of the heat load onto the calorimeter can be measured. (2) Measurement under the relatively high heat flux environment is possible . (3) The calorimetric measurement under continuous and steady-state heat l oad environment is also possible. The verification of the measurement princ iple was done using an NB-injection system on the compact helical system (C HS) at the National Institute for Fusion Science (NIFS). The measured NB po wer densities are compared to the power densities being evaluated by the CH S-NB profile database. It was experimentally confirmed that the time consta nt of the measurement is about 7 ms. (C) 2001 American Institute of Physics .