A multi-channel spectroscopic system for measuring impurity ion temperatures and poloidal rotation velocities in TJ-II

Citation
A. Baciero et al., A multi-channel spectroscopic system for measuring impurity ion temperatures and poloidal rotation velocities in TJ-II, REV SCI INS, 72(1), 2001, pp. 971-974
Citations number
13
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN journal
00346748 → ACNP
Volume
72
Issue
1
Year of publication
2001
Part
2
Pages
971 - 974
Database
ISI
SICI code
0034-6748(200101)72:1<971:AMSSFM>2.0.ZU;2-6
Abstract
In this article, we report on the hardware and software of an eight-channel , high-resolution, spectroscopic diagnostic system that has been built for the TJ-II flexible heliac. This system is currently being used on TJ-II to measure impurity ion temperature and poloidal rotation using passive emissi on spectroscopy. The principal features of the diagnostic include independe nt focusing of its channels, high sensitivity for performing Doppler measur ements in low-density ECR-heated plasmas, as well as a flexible and fast in -house-developed software program for performing integrated data reduction and analysis. (C) 2001 American Institute of Physics.