Performance of the first RPC station prototype for the CMS barrel detector

Citation
M. Abbrescia et al., Performance of the first RPC station prototype for the CMS barrel detector, NUCL INST A, 456(1-2), 2000, pp. 103-108
Citations number
4
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
456
Issue
1-2
Year of publication
2000
Pages
103 - 108
Database
ISI
SICI code
0168-9002(200012)456:1-2<103:POTFRS>2.0.ZU;2-#
Abstract
A full-size prototype of the second barrel RPC station (RB2) for the CMS de tector has been tested under high-irradiation flux at the CERN Gamma Irradi ation Facility (GIF) during the 1999 beam test. The main requirements of RP Cs as trigger detector have been studied: cluster size, time resolution, ef ficiency and rate capability. The timing features of a new front-end electr onics were also investigated. Only the results obtained with the detector w orking in single-gap mode are reported here. (C) 2000 Elsevier Science B.V. All rights reserved.