Gas holdup in flotation columns: laboratory measurements

Citation
Fj. Tavera et al., Gas holdup in flotation columns: laboratory measurements, INT J MINER, 61(1), 2001, pp. 23-40
Citations number
16
Categorie Soggetti
Geological Petroleum & Minig Engineering
Journal title
INTERNATIONAL JOURNAL OF MINERAL PROCESSING
ISSN journal
03017516 → ACNP
Volume
61
Issue
1
Year of publication
2001
Pages
23 - 40
Database
ISI
SICI code
0301-7516(200101)61:1<23:GHIFCL>2.0.ZU;2-6
Abstract
The gas holdup in laboratory flotation columns was measured using a conduct ivity probe. Measurements in a 50-cm-diameter flotation column have shown t hat gas holdup varies radially depending on the sparging system array, surf actants addition, and spargers malfunctions. The column was run in two mode s: unbaffled (open), and baffled(vertically). Radial differences in gas hol dup are enhanced by using baffles if gas is not uniformly injected through the spargers in the flotation column; however, the gas holdup is the same a mong the quadrants of the baffled column when the gas is evenly injected. D rift flux analysis was applied to estimate bubble size; it was a bubble siz e radial distribution in the column that was consistent with the gas holdup . (C) 2001 Elsevier Science B.V. All rights reserved.