The modification of the variation quantum measurement is considered, which
allows to eliminate the main shortcoming of such a measurement - the meter
hardware setup dependence on the signal shape and arrival time. This method
is based on approximation of the signal by series of short rectangular "sl
ices" and periodical applying the Variation measurement procedure fitted to
such a rectangular pulse. It allows to reconstruct the signal shape with p
recision not limited by the standard quantum limit. "Price", in the case of
the parametric position meters (including interferometric ones), is pumpin
g energy 720/pi (4) approximate to 7.4 times higher than for the usual vari
ation measurement. (C) 2000 Elsevier Science B.V. All rights reserved.