A monitor of beam polarization profiles for the TRIUMF parity experiment

Citation
Ar. Berdoz et al., A monitor of beam polarization profiles for the TRIUMF parity experiment, NUCL INST A, 457(1-2), 2001, pp. 288-298
Citations number
23
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
457
Issue
1-2
Year of publication
2001
Pages
288 - 298
Database
ISI
SICI code
0168-9002(20010111)457:1-2<288:AMOBPP>2.0.ZU;2-G
Abstract
TRIUMF experiment E497 is a study of parity violation in pp scattering at a n energy where the leading term in the analyzing power is expected to vanis h, thus measuring a unique combination of weak-interaction flavor-conservin g terms. It is desired to reach a level of sensitivity of 2 x 10(-8) in bot h statistical and systematic errors. The leading systematic errors depend o n transverse polarization components and, at least, the first moment of tra nsverse polarization. A novel polarimeter that measures profiles of both tr ansverse components of polarization as a function of position is described. (C) 2001 Elsevier Science B.V. All rights reserved.