SUBSLAB VENTILATION SYSTEM - INSTALLATION AND FOLLOW-UP IN A HIGH-RADON HOUSE IN BRITTANY, FRANCE

Citation
Yc. Bonnefous et al., SUBSLAB VENTILATION SYSTEM - INSTALLATION AND FOLLOW-UP IN A HIGH-RADON HOUSE IN BRITTANY, FRANCE, Environment international, 22, 1996, pp. 1069-1072
Citations number
4
Categorie Soggetti
Environmental Sciences
Journal title
ISSN journal
01604120
Volume
22
Year of publication
1996
Supplement
1
Pages
1069 - 1072
Database
ISI
SICI code
0160-4120(1996)22:<1069:SVS-IA>2.0.ZU;2-7
Abstract
A subslab ventilation system was designed and installed in a high rado n house in Brittany, France. Radon concentration in the basement of th is house was reduced from an average 10 000 Bq/m(3) to less than 200 B q/m(3), thanks to a subslab depressurization system with a double barr ier and a 32 W fan. Sealing the concrete slab cracks greatly improved the system performance. Finally, the feasibility of using a passive do uble barrier ventilation system is shown. Copyright (C) 1996 Elsevier Science Ltd.