Ma. Guenin, Benign intraductal papilloma: Diagnosis and removal at stereotactic vacuum-assisted directional biopsy guided by galactography, RADIOLOGY, 218(2), 2001, pp. 576-579
Citations number
7
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Journal title
RADIOLOGY
ISSN journal
00338419 → ACNP
Volume
218
Issue
2
Year of publication
2001
Pages
576 - 579
Database
ISI
SICI code
0033-8419(200102)218:2<576:BIPDAR>2.0.ZU;2-R
Abstract
Galactography was performed in women who had problematic nipple discharge. In five women who had a focal intraductal filling defect, immediate stereot actic vacuum-assisted directional biopsy of the filling defect was performe d; results were a benign intraductal papilloma in each, with atypia in one. In the four women who did not have atypia, the procedure was diagnostic an d appears to have been therapeutic as well, since nipple discharge ceased a fter the procedure.