Failure analysis of turbo-generator of a 10 MW captive power plant

Citation
N. Parida et S. Tarafder, Failure analysis of turbo-generator of a 10 MW captive power plant, ENG FAIL AN, 8(3), 2001, pp. 303-309
Citations number
3
Categorie Soggetti
Mechanical Engineering
Journal title
ENGINEERING FAILURE ANALYSIS
ISSN journal
13506307 → ACNP
Volume
8
Issue
3
Year of publication
2001
Pages
303 - 309
Database
ISI
SICI code
1350-6307(200106)8:3<303:FAOTOA>2.0.ZU;2-T
Abstract
The failure analysis of a disc and a few of the rotor parts of a turbo-gene rator of a 10 MW captive power plant has been made. It was found that a par t of the rim of the 23rd disc, which had cracked by fatigue, became unstabl e and was flung off. This hit the diaphragm and the diaphragm carrier in it s vicinity and led to their catastrophic failure. (C) 2001 Elsevier Science Ltd. All rights reserved.