Total dose test of commercial off-the-shelf components to be used in powersupply for space experiments

Citation
M. Menichelli et al., Total dose test of commercial off-the-shelf components to be used in powersupply for space experiments, IEEE NUCL S, 47(6), 2000, pp. 1879-1884
Citations number
8
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
ISSN journal
00189499 → ACNP
Volume
47
Issue
6
Year of publication
2000
Part
1
Pages
1879 - 1884
Database
ISI
SICI code
0018-9499(200012)47:6<1879:TDTOCO>2.0.ZU;2-H
Abstract
Commercial off-the-shelf components have been tested for their use on the p ower supplies of the AMS and PAMELA experiments. The test has been performe d using the CALLIOPE Co60 source at the Casaccia (Rome -Italy) Laboratory o f ENEA according to the ESA/SCC 22900 specifications. The total dose for th is test was 30 krads. Measurements of relevant parameters for each componen t has been taken at 3, 10 and 30 krads. Annealing and ageing has also been perfomed according to the ESA specification. The results on the degradation of performaces in discrete transistors, Op-Amps, regulators and other anal og and digital components are reported.