This paper is devoted to the study of a new triggering scheme for discharge
initiation of vacuum snitches. The device, which mainly comprises a carbon
bridge, is characterized by its Ion dimension and energy consumption. Fast
imaging techniques coupled to electric measurements and spectroscopic inve
stigations have allowed us to characterize the spatiotemporal evolution of
the physical processes resulting in the triggering.