ELECTRON COOLING AT CRYRING WITH AN EXPANDED ELECTRON-BEAM

Authors
Citation
H. Danared, ELECTRON COOLING AT CRYRING WITH AN EXPANDED ELECTRON-BEAM, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 391(1), 1997, pp. 24-31
Citations number
28
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
391
Issue
1
Year of publication
1997
Pages
24 - 31
Database
ISI
SICI code
0168-9002(1997)391:1<24:ECACWA>2.0.ZU;2-8
Abstract
Studies of electron cooling with an adiabatically expanded electron be am have been performed at CRYRING. Measurements of the longitudinal dr ag force using three different methods are described and are compared with measurements at other electron coolers. The processes that determ ine the electron temperature, longitudinally and transversally, are re viewed, and the effect of the beam expansion on these processes is dis cussed. It is described how the electron temperature can influence the outcome of recombination measurements, and how such measurements can be used to determine the electron temperature. and an example of such a measurement is given.