Use of gamma-ray-generating nuclear reactions for temperature diagnostics of DT fusion plasma - art. no. 026413
Citation
Vt. Voronchev et al., Use of gamma-ray-generating nuclear reactions for temperature diagnostics of DT fusion plasma - art. no. 026413, PHYS REV E, 6302(2), 2001, pp. 6413
Categorie Soggetti
Physics
Journal title
PHYSICAL REVIEW E
SICI code
1063-651X(200102)6302:2<6413:UOGNRF>2.0.ZU;2-2
Abstract
A diagnostic application of gamma rays emitted in Li-6+D and Li-6+T nuclear
reactions induced by admiring a small amount of Li-6 in DT fusion plasma i
s investigated. It is shown that the reaction-produced monochromatic gamma
quanta with energies E-gamma = 0.429, 0.478, and 0.981 MeV can be used for
ion temperature measurements in DT plasma. The proposed measurements are ex
pected to be essentially independent of the plasma density and its local fl
uctuations. The required reaction cross sections and the Maxwellian rate pa
rameters of the Li-6+T gamma -ray production are calculated within a realis
tic nuclear model.