The effects of harmonic voltages generated by the voltage-source inverter w
ithin a dynamic voltage restorer can be mitigated through the use of a line
-side filter. However, injudicious design of the harmonic-filtering system
can degrade the power-quality-enhancement capability of the restorer. Inapp
ropriate filter design may also result in the need for the inverter current
rating to be increased significantly. The purpose of the investigation is
therefore to carry out a systematic analysis of the filter design by consid
ering first the selection of the filter-capacitor on the basis of meeting a
prespecified harmonic-performance criterion. The effect of the capacitor o
n the inverter rating is then evaluated and the method of determining the f
ilter capacity is presented. An example, which involves electromagnetic tra
nsient studies, is included to demonstrate the efficacy of the proposed des
ign method.