Ph. Chen et al., An improved data reduction method for transient liquid crystal thermography on film cooling measurements, INT J HEAT, 44(7), 2001, pp. 1379-1387
This study proposes an improved data reduction method for the applications
of transient liquid crystal thermography on film cooling effectiveness meas
urements. On the evaluations of film cooling effectiveness and heat transfe
r coefficient, an "equivalent step temperature"(EST) is proposed to replace
the Duhamel's superposition principle which is conventionally used to acco
unt for the actual temperature rises in both free-stream and injection flow
s rather than the ideal step temperature changes. For obtaining both values
at over thousands of measured locations, the current data reduction method
can effectively reduce the calculation time as compared with the conventio
nal Duhamel's superposition method, but adds only negligible errors. (C) 20
01 Elsevier Science Ltd. All rights reserved.