Focusing hard X-ray with a single lens

Citation
Yp. Zhang et al., Focusing hard X-ray with a single lens, JPN J A P 2, 40(1AB), 2001, pp. L75-L77
Citations number
12
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Volume
40
Issue
1AB
Year of publication
2001
Pages
L75 - L77
Database
ISI
SICI code
Abstract
We show that a 10 keV X-ray has been focused into 3.4-8.4 mum at a focal le ngth F = 0.4-1.5 m with a single refractive lens and such X-ray microbeams: can be generated in array. For the beam from a synchrotron radiation sourc e, which typically had a diameter phi = 100 mum, transmissions of our lense s were measured to be T = 54-85%. X-ray imaging of a copper mesh was carrie d out with a magnification of about 5 in one dimension and the imaging reso lution was evaluated to be 0.9 mum. Our lenses have performed well under a flux of 1.1 x 10(11) photons.s(-1).mm(-2), showing no visible damage due to the X-ray exposure.