Purpose: To investigate the effect of one-bottle dentin bonding systems on
pulpal hemorrhage control in direct pulp exposures through contraction of p
ulp blood vessels using the rat carotid artery model. Materials and Methods
: Four dentin bonding agents (Prime & Bond 2.1, Prime & Bond NT, Syntac Sin
gle Component and Single Bond) were used. The efficacy of bonding agents we
re compared to that of epinephrine (control) in the viewpoint of the concen
tration applied and the contraction forces induced on the smooth muscle wer
e recorded using a force displacement transducer. Results: Three of the tes
t materials produced epinephrine-like contractions on the rat carotid arter
y (smooth muscle) while no reading could be achieved with Single Bond. A ra
nking between the bonding agents for contraction forces was obtained as fol
lows: Prime & Bond NT > Prime & Bond 2.1 > Syntac Single Component (P < 0.0
5).