Measurement of absorbed dose distributions in a plastic phantom irradiatedby 40-and 65-MeV quasi-monoenergetic neutrons

Citation
Y. Nakane et Y. Sakamoto, Measurement of absorbed dose distributions in a plastic phantom irradiatedby 40-and 65-MeV quasi-monoenergetic neutrons, NUCL INST A, 459(3), 2001, pp. 552-564
Citations number
37
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
459
Issue
3
Year of publication
2001
Pages
552 - 564
Database
ISI
SICI code
0168-9002(20010301)459:3<552:MOADDI>2.0.ZU;2-A
Abstract
In order to validate dose evaluation methods for radiation shielding design of accelerator facilities, absorbed dose distributions in a plastic phanto m of 30 x 30 x 30 cm(3) slab were measured for 40- and 65-MeV quasi-monoene rgetic neutrons with a tissue-equivalent proportional counter and a tissue- equivalent ionization chamber. The measured distributions were compared wit h the calculated ones from the energy deposition of charged particles and n eutron energy spectra by using the Monte Carlo codes, HETC-3STEP and MORSE- CG/KFA, respectively. As a result, it was revealed that the calculation met hod used in the present work was applicable to absorbed dose evaluation for intermediate energy neutrons with high accuracy. (C) 2001 Elsevier Science B.V. All rights reserved.