A proposed diagnostic survey procedure for cob walls

Citation
L. Keefe et al., A proposed diagnostic survey procedure for cob walls, P I CIV E S, 146(1), 2001, pp. 57-65
Citations number
15
Categorie Soggetti
Civil Engineering
Journal title
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS
ISSN journal
09650911 → ACNP
Volume
146
Issue
1
Year of publication
2001
Pages
57 - 65
Database
ISI
SICI code
0965-0911(200102)146:1<57:APDSPF>2.0.ZU;2-K
Abstract
Following the publication of the systematic analysis of some 20 failed cob buildings, this paper proposes a diagnostic survey procedure for cob walls. The earth building research team at the University of Plymouth has been st udying the causes of structural failure both by laboratory studies and obse rved material based upon real building failures. A definition of a healthy cob building is presented, and this is followed by an outlined check-list w hereby unsound cob walls may be identified. This survey check-list has six steps: (1) a site analysis, (2) building description, (3) maintenance and r epair history, (4) building condition, (5) a moisture content analysis, and (6) a cob material composition analysis. There is a need to refine and dev elop the proposed survey procedure in order to establish a working tool tha t building surveyors can use in the field, which would include a troublesho oting guide, and the discussion addresses the main issues.