Following the publication of the systematic analysis of some 20 failed cob
buildings, this paper proposes a diagnostic survey procedure for cob walls.
The earth building research team at the University of Plymouth has been st
udying the causes of structural failure both by laboratory studies and obse
rved material based upon real building failures. A definition of a healthy
cob building is presented, and this is followed by an outlined check-list w
hereby unsound cob walls may be identified. This survey check-list has six
steps: (1) a site analysis, (2) building description, (3) maintenance and r
epair history, (4) building condition, (5) a moisture content analysis, and
(6) a cob material composition analysis. There is a need to refine and dev
elop the proposed survey procedure in order to establish a working tool tha
t building surveyors can use in the field, which would include a troublesho
oting guide, and the discussion addresses the main issues.