HELIUM REFRIGERATION SYSTEM FOR A LIQUID-HYDROGEN RAPID-CYCLING BUBBLE-CHAMBER

Citation
En. Ardashev et al., HELIUM REFRIGERATION SYSTEM FOR A LIQUID-HYDROGEN RAPID-CYCLING BUBBLE-CHAMBER, Instruments and experimental techniques, 40(2), 1997, pp. 159-169
Citations number
9
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
00204412
Volume
40
Issue
2
Year of publication
1997
Pages
159 - 169
Database
ISI
SICI code
0020-4412(1997)40:2<159:HRSFAL>2.0.ZU;2-Y
Abstract
A double-loop helium refrigeration system is developed to stabilize th e operating conditions of a liquid-hydrogen rapid-cycling bubble chamb er. The system makes it possible to reduce the amount of liquid hydrog en used to a minimum and thus to localize the dangerously explosive zo ne within the boundaries of the vacuum housing. Under operating condit ions, the system maintains temperature and pressure to an accuracy of +/-0.005 K and +/-0.01 atm, respectively, Consumption of liquid helium is within 60 1/day.