Amperometric flow-injection determination of sucrose with a mediated tri-enzyme electrode based on sucrose phosphorylase and electrocatalytic oxidation of NADH
E. Maestre et al., Amperometric flow-injection determination of sucrose with a mediated tri-enzyme electrode based on sucrose phosphorylase and electrocatalytic oxidation of NADH, BIOSENS BIO, 16(1-2), 2001, pp. 61-68
A new sucrose electrode is described for the determination of sucrose witho
ut interference from glucose or fructose. The sucrose electrode is based on
the tri-enzymatic system of sucrose phosphorylase, phosphoglucomutase and
glucose-6-phosphate 1-dehydrogenase. where NAD(P)H is produced from the las
t enzymatic reaction and recycled into NAD(P)(+) through its electrocatalyt
ic oxidation by Os(4,4'-dimethvl-2.2-bypyridine)(2)(1, 10-phenanthroline-5.
6-dione). The electrodes were optimised with respect to the various constru
ction parameters and carrier composition in a FIA system and their response
as a function of the pH and flow-rate was examined. The electrodes were su
itable for operation in a FIA system and the analysis of real samples showe
d good agreement with the reference method. Typical optimised electrodes sh
owed detection limits of 1 mM sucrose. response time of 5 min, sensitivity
1.010 nA mM(-1). and current density of 8.38 muA cm(-2), using 200 mM PIPES
pH 7.25 with 10 mM phosphate and 5 mM MgCl2 as carrier. (C) 2001 Elsevier
Science B.V. All rights reserved.